Peltier
About UsContact UsSite MapHelp
Phone Number 443-926-9135
 

Built to Order TEC's

Our Built-To-Order TECs to fill your special requirements.

  • These TECs can be Built-To-Order with a minimum 10 piece purchase and a 5-6 week lead time.
  • Standard versions capable of withstanding temperatures up to 125°C. Call for high temperature versions capable of up to 200°C.
  • Call 443-926-9135 for larger volume pricing and availability.
RoHS Built to Order TEC's
 
Sorted by Imax
 
  • Click part # to view HTML spec. sheet.
  • Click Adobe PDF2 icon for PDF2 spec. sheet or right-click to download.
Dimensions mm (inches)

Prices

 

  Click to Sort Click to Sort Click to Sort   Click to Sort  
Part #1
PDF
N

Imax (Amps)

Qmax (Watts)

Vmax (Volts)

dTmax (°C)

A

B

C

H

10-24 pcs 25-49 pcs
06301-5L31-03CF

63 3.0 12.7 7.62 67 15 (0.59) 15 (0.59) 15 (0.59) 3.6 (.142)    
                         
01711-5L31-03CF
17 3.3 3.9 1.9 67 15 (0.59) 15 (0.59) 15 (0.59) 4.7 (.185)    
04911-5L31-03CK
49 3.3 11.3 5.6 67 25 (0.98) 25 (0.98) 25 (0.98) 4.7 (.185)    
07111-5L31-03CL
71 3.3 16.4 8.1 67 30 (1.18) 30 (1.18) 30 (1.18) 4.7 (.185)    
                         
01711-5L31-04CF
17 3.9 4.48 2.1 67 15 (0.59) 15 (0.59) 15 (0.59) 4.7 (.185)    
03111-5L31-04CG
31 3.9 8.15 3.8 67 20 (0.79) 20 (0.79) 20 (0.79) 4.7 (.185)    
04911-5L31-04CK
49 3.9 12.9 5.8 67 25 (0.98) 25 (0.98) 25 (0.98) 4.7 (.185)    
                         
01711-5L31-05CF
17 4.6 5.5 2.1 67 15 (0.59) 15 (0.59) 15 (0.59) 4.0 (.157)    
03111-5L31-05CG
31 4.6 10 3.8 67 20 (0.79) 20 (0.79) 20 (0.79) 4.0 (.157)    
04911-5L31-05CK
49 4.6 15.8 5.8 67 25 (0.98) 25 (0.98) 25 (0.98) 4.0 (.157)    
07111-5L31-05CL
71 4.6 22.8 8.5 67 30 (1.18) 30 (1.18) 30 (1.18) 4.0 (.157)    
12711-5L31-05CQ
127 4.6 33.4 15.4 67 40 (1.57) 40 (1.57) 40 (1.57) 4.0 (.157)    
                         
00711-5L31-06CB
7 6.0 2.8 0.9 68 10 (0.39) 10 (0.39) 10 (0.39) 3.8 (.150)    
01711-5L31-06CF
17 6.0 8.9 2.1 68 15 (0.59) 15 (0.59) 15 (0.59) 3.8 (.150)    
03111-5L31-06CG
31 6.0 12.5 3.8 68 20 (0.79) 20 (0.79) 20 (0.79) 3.8 (.150)    
                         
00711-5L31-08CB
7 8.5 3.8 0.9 68 10 (0.39) 10 (0.39) 10 (0.39) 3.3 (.130)    
01711-5L31-08CF
17 8.5 9.2 2.1 68 15 (0.59) 15 (0.59) 15 (0.59) 3.3 (.130)    
03111-5L31-08CG
31 8.5 16.8 3.8 68 20 (0.79) 20 (0.79) 20 (0.79) 3.3 (.130)    
07111-5L31-08CL
71 8.5 38.5 8.6 68 30 (1.18) 30 (1.18) 30 (1.18) 3.3 (.130)    
12711-5L31-08CW
127 8.5 81 15.4 68 50 (1.97) 50 (1.97) 50 (1.97) 3.3 (.130)    
                         
 
 

1. Please specify any Options by adding the Option Code(s) to the end of the part number.

2. Adobe Acrobat® must be installed on your computer to view and print these files. Click on the "Get Acrobat Reader" image to download and Install it.
NOTE: Default Maximum operating temperature is 125°C unless color coded. Red highlighted part numbers have a maximum operating temperature of 200°C. Gray highlighted part numbers have a maximum operating temperature of 110°C.

Built to Order TEC's

Definitions:
I Input Amps to the TEC (in Amps)
Imax  Input Amps that produce the maximum dT [dTmax] (in Amps)
Qc  Amount of heat that can be absorbed at the cold side face of the TEC (in watts)
Qmax  Maximum amount of heat that can be absorbed at the cold side. This occurrs at I = Imax and when dT = 0. (in Watts)
Th  Temperature of the hot side face of the TEC (in °C)
Tc  Temperature of the cold side face of the TEC (in °C)
dT  Difference in temperature between the hot side (Th) and the cold side (Tc). dT = Th-Tc (in °C)
dTmax  Maximum difference in temperature a TEC can achieve between the hot side (Th) and the cold side (Tc). This occurrs at I = Imax and when Qc = 0. (in °C)
Vmax Voltage at I = Imax (in Volts)

 

HOME    ABOUT US    CONTACT US    HELP